Add to Favorites
Share

4 Way Cassette Fan Coil Unit (E) without Pump

  • Description
Product Detail

    4-way cassette fan coil unit (E) without pump 

    Four way cassette type fan coil unit (E) the product have passed ISO 9001 and CE certificate, we offer 18 months warranty. 

    We supply four way cassette fan coil unit which passed ISO 9001 and CE certificate. The unit has 18 months warranty. Our companies focus on fan coil unit producing for 10 years. We are expecting become your long-term partner in China.


    Product introduction of four way cassette fan coil unit (E) with pump.

    MECO’s cassette type fan coil unit is developed by long time producing and selling experience. As a complex product in this field, cassette type fan coil unit is always a hard point for many manufactories. MECO’s E style 4-way cassette type fan coil unit have The M style cassette fan coil unit is our core competitiveness which has high stability and comprehensive function.


    Products specification of four way cassette fan coil unit (M) with pump.


    PERFORMANCE OF CASSETTE TYPE FAN COIL(4-WAY,2 TUBE)---DRAINED BY WATER PUMP
    model(2 tube system) MFP-34KM-(Q)EE1 MFP-51KM-(Q)EE1 MFP-68KM-(Q)EE1 MFP-85KM-(Q)EE2 MFP-102KM-(Q)EE2 MFP-136KM-(Q)EE3 MFP-170KM-(Q)EE3 MFP-204KM-(Q)EE3
    model MFP-34KM-(Q)E1 MFP-51KM-(Q)E1 MFP-68KM-(Q)E1 MFP-85KM-(Q)E2 MFP-102KM-(Q)E2 MFP-136KM-(Q)E3 MFP-170KM-(Q)E3 MFP-204KM-(Q)E3
    model of panel MB-S****E1 MB-S****E2 MB-S****E3
    power supply 220V,50Hz,1Ph
    air volume H m3/h 340 510 680 850 1020 1360 1700 2040
    M 280 380 515 660 765 1040 1280 1550
    L 180 260 340 430 530 710 860 1050
    static pressure Pa 0 0 0 0 0 0 0 0
    cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800
    BTU/h 6142 9212 12283 15354 18425 24566 30708 36850
    SH W 1311 1971 2700 3184 4196 5362 6707 8072
    BTU/h 4473 6725 9212 10864 14317 18295 22884 27542
    TH M W 1500 2460 3000 3715 4423 6435 7848 9296
    SH W 994 1555 1995 2426 3041 4236 5393 6603
    TH L W 1391 2057 2479 2921 3793 5604 7223 8534
    SH W 823 1200 1530 1826 2373 3284 4416 5248
    heating capacity H W 2700 4050 5400 6750 8100 10800 13500 16200
    M W 1949 2770 3938 4902 5694 7924 10473 12997
    L W 1297 1774 2779 3505 3876 5421 6992 8645
    noise H 0Pa dB(A) 37 39 41 43 45 46 48 50
    power input H 0Pa W 37 52 62 76 96 134 152 189
    waterflow volume m3/h 0.31 0.46 0.62 0.77 0.93 1.23 1.54 1.85
    water pressure dropping kPa 11.8 11.8 22.4 27 29.6 29.6 35.4 35.4
    dimension of water(in & out)connection pipe in ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
    out ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
    coil type high efficient copper pipe to wear Hydrophilic aluminum coil
    dimension of water drain pipe mm ?26 ?26 ?26 ?26 ?26 ?26 ?26 ?26
    net dimension unit L×W×H     mm 590*590*270 752*752*293 822*822*253 822*822*293
    panel 650*650*45 850*850*45 950*950*45
    net weight unit kg 19 19 20 23 23 25 28 28
    panel 2.2 4.5 6


    blob.png


    PERFORMANCE OF CASSETTE TYPE FAN COIL(4-WAY,2 TUBE)---DRAINED BY NATURE
    model(2 tube system) MFP-34KM-(Q)EE1 MFP-51KM-(Q)EE1 MFP-68KM-(Q)EE1 MFP-85KM-(Q)EE2 MFP-102KM-(Q)EE2 MFP-136KM-(Q)EE3 MFP-170KM-(Q)EE3 MFP-204KM-(Q)EE3 MFP-238KM-(Q)EE3
    model MFP-34KM-(Q)E1 MFP-51KM-(Q)E1 MFP-68KM-(Q)E1 MFP-85KM-(Q)E2 MFP-102KM-(Q)E2 MFP-136KM-(Q)E3 MFP-170KM-(Q)E3 MFP-204KM-(Q)E3 MFP-238KM-(Q)E3
    model of panel MB-S****E1 MB-S****E2 MB-S****E3
    power supply 220V,50Hz,1Ph
    air volume H m3/h 340 510 680 850 1020 1360 1700 2040 2380
    M 280 380 515 660 765 1040 1280 1550 1800
    L 180 260 340 430 530 710 860 1050 1280
    static pressure Pa 0 0 0 0 0 0 0 0 0
    cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
    BTU/h 6142 9212 12283 15354 18425 24566 30708 36850 42991
    SH W 1311 1971 2700 3184 4196 5362 6707 8072 9070
    BTU/h 4473 6725 9212 10864 14317 18295 22884 27542 30947
    TH M W 1500 2460 3000 3715 4423 6435 7848 9296 10500
    SH W 994 1555 1995 2426 3041 4236 5393 6603 7190
    TH L W 1391 2057 2479 2921 3793 5604 7223 8534 8900
    SH W 823 1200 1530 1826 2373 3284 4416 5248 5500
    heating capacity H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
    M W 1949 2770 3938 4902 5694 7924 10473 12997 13900
    L W 1297 1774 2779 3505 3876 5421 6992 8645 9700
    noise H 0Pa dB(A) 37 39 41 43 45 46 48 50 51
    power input H 0Pa W 37 52 62 76 96 134 152 189 228
    waterflow volume m3/h 0.31 0.46 0.62 0.77 0.93 1.23 1.54 1.85 2.16
    water pressure dropping kPa 11.8 11.8 22.4 27 29.6 29.6 35.4 35.4 40
    dimension of water(in & out)connection pipe in ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
    out ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
    coil type high efficient copper pipe to wear Hydrophilic aluminum coil
    dimension of water drain pipe mm ?26 ?26 ?26 ?26 ?26 ?26 ?26 ?26 ?26
    net dimension unit L×W×H     mm 590*590*420 752*752*443 822*822*403 822*822*443
    panel 650*650*45 850*850*45 950*950*45
    net weight unit kg 19 19 20 23 23 25 28 28 29
    panel 2.2 4.5 6



    blob.png


    PERFORMANCE OF CASSETTE TYPE FAN COIL(4-WAY,4 TUBE)---DRAINED BY WATER PUMP
    model(4 tube system) MFP-34KM4-(Q)EE1 MFP-51KM4-(Q)EE1 MFP-68KM4-(Q)EE1 MFP-85KM4-(Q)EE2 MFP-102KM4-(Q)EE2 MFP-136KM4-(Q)EE3 MFP-170KM4-(Q)EE3 MFP-204KM4-(Q)EE3 MFP-238KM4-(Q)EE3
    model MFP-34KM4-(Q)E1 MFP-51KM4-(Q)E1 MFP-68KM4-(Q)E1 MFP-85KM4-(Q)E2 MFP-102KM4-(Q)E2 MFP-136KM4-(Q)E3 MFP-170KM4-(Q)E3 MFP-204KM4-(Q)E3 MFP-238KM4-(Q)E3
    model of panel MB-S****E1 MB-S****E2 MB-S****E3
    power supply 220V,50Hz,1Ph
    air volume H m3/h 340 510 680 850 1020 1360 1700 2040 2380
    M 280 380 515 660 765 1040 1280 1550 1800
    L 180 260 340 430 530 710 860 1050 1280
    static pressure Pa 0 0 0 0 0 0 0 0 0
    cooling capacity TH H W 1350 2030 2700 3380 4050 5400 6750 8100 9450
    BTU/h 4606 6926 9212 11533 13819 18425 23031 27637 32243
    SH W 1010 1520 2080 2450 3230 4130 5160 6220 6989
    BTU/h 3446 5186 7097 8359 11021 14092 17606 21223 23846
    TH M W 1130 1850 2250 2790 3320 4830 5890 6970 7873
    SH W 770 1200 1540 1870 2340 3260 4150 5080 5532
    TH L W 1040 1540 1860 2190 2840 4200 5420 6400 6674
    SH W 630 920 1180 1410 1830 2530 3400 4040 4234
    heating capacity H W 1080 1620 2160 2700 3240 4320 5400 6480 7560
    M W 780 1108 1575 1961 2278 3170 4189 5199 5560
    L W 519 710 1112 1402 1550 2168 2797 3458 3880
    noise H 0Pa dB(A) 37 39 41 43 45 46 48 50 51
    power input H 0Pa W 37 52 62 76 96 134 152 189 228
    waterflow volume Cooling m3/h 0.23  0.35  0.46  0.58  0.69  0.93  1.16  1.39  1.60 
    waterflow volume heating 0.09  0.14  0.19  0.23  0.28  0.37  0.46  0.56  0.70 
    water pressure dropping cooling  kPa 8.26 8.26 15.68 18.9 20.72 20.72 24.78 24.78 40
    heating 3.54 3.54 6.72 8.1 8.88 8.88 10.62 10.62 16
    dimension of water(in & out)connection pipe cooling/heating ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
    ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
    coil type high efficient copper pipe to wear Hydrophilic aluminum coil
    dimension of water drain pipe mm ?26 ?26 ?26 ?26 ?26 ?26 ?26 ?26 ?26
    net dimension (with pump) unit L×W×H     mm 590*590*270 752*752*293 822*822*253 822*822*293
    (without pump) unit 590*590*420 752*752*443 822*822*413 822*822*443
    panel 650*650*45 850*850*45 950*950*45
    net weight unit kg 20 20 21 24 24 26 29 29 30
    panel 2.2 4.5 6


    blob.png


    Products Feature and details

    1 Distinctive panel design      

    *4-way air flowing, which can uniform temperature distribution in the room. Elegant appearance can let our fan coil unit match different decoration style. The wind guide vane of E-style cassette type fan coil unit is flocked. The flocked guide van can prevent condensation water backflow effectively 

    2 Easy to be installed, low installation cost. 

    3 Remote controller is standard and wire controller is optional 

    4 Excellent performance-Integral C type heat exchanger

     *All adopt the design of integral C type structure, well-distributed air volume and high-efficient heat exchange ;

    image001.pngimage003.png

     

    5 The efficiency of airflow rate, heavy wind volume and low noise is excellent. Because the ventilator wheel is processed to sine strip seam, which enhance its flexibility and drops the vibration of ventilator during revolving in large scale simultaneously reduced the motor noise caused by ventilator swinging.

     

    image006.gifimage008.gif

     

    6 This unit is natural drainage. 

    7 The structure of the unit is easy for maintaining fan and fan motor. 

    8 Internal electrical box.

    Without access port, our E-style cassette type fan coil unit still can maintain the control system 

    9 Left/right water tube connection can be selected 

    10 4-tube system is optional

    11 Water valve can be installed inside the unit.

     

    Product certification:


    image0011.png

    image003.png


    Packing and shipping

    Normally we use carton packing. The carton box printed with our MECO brand and unique color and pattern. We also have strong packing as optional. Depends on customers needs, we have crates, pallets, or honeycomb box etc. Our FOB port is NINGBO, China port.


    image006.gifimage008.gifimage010.gif


    FAQ.

    Q:Can you manufactury do OEM for our company?

    A: Yes of course. As a specialized manufacturer and exporter for this product in China, we sincerely hope to establish business relations with your esteemed corporation. Now we do OEM/ODM for a lot of famous brands in China and other countries, such as, KingAir, QingHuaTongFang,TCL,AUX,CHIGO,LS,etc.

     

    Q: How long is your products delivery time?

    A: Normally we will finish producing in 20 days. For export order, The delivery time will be 35~60 days. The delivery time also depends on quantity of order.

     

    Q: Our hotel want to choose the fan coil unit which have 4 pipe system, do you have this one?

    A: Yes, Most of our products have 4 pipe system as optional.

     

    Q: The price of DC motor is higher than AC one. Whether the DC motor is really better than AC motor?

    A: The energy consumption for motor is changed to energy for running and heating, the efficiency of AC motor is always 40~45%, that means there have 55%~60% energy was transfered to heat. The heat might cause to the aging of components, which is harm to the life of motor. The efficiency of DC brushless motor is always more than 80%~95%, which have only little energy change during heating. Because of that, DC motor do much better on energy saving than AC one.

     


Send your message to this supplier
To:  

Taizhou MECO Refrigeration Equipment Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>