Water cassette fan coil unit (M) with pump
MECO water cassette type fan coil unit (M) style which passed ISO 9001 and CE certificate, it has 18 months warranty
Product introduction of water cassette fan coil unit (M) with pump.
MECO’s cassette type fan coil unit is developed by long time producing and selling experience. MECO start to produce the old design cassette type fan coil unit in 2001. The 4 way air blowing can offer widely range of air support. Now, we have completely models of M style cassette type fan coil unit and EC motor one. The M style cassette fan coil unit is our core competitiveness which has high stability and comprehensive function.
Products specification of water cassette fan coil unit (M) with pump.
PERFORMANCE OF "M" STYLE CASSETTE TYPE FAN COIL(4-WAY,2TUBE)---DRAINED BY WATER PUMP | |||||||||||||||
model(2 tube system) | MFP-34KM-(Q)MK1 | MFP-51KM-(Q)MK1 | MFP-68KM-(Q)MK1 | MFP-80KM-(Q)MK1 | MFP-85KM-(Q)MK2 | MFP-102KM-(Q)MK2 | MFP-136KM-(Q)MK2 | MFP-136KM-(Q)MK3 | MFP-153KM-(Q)MK3 | MFP-170KM-(Q)MK3 | MFP-204KM-(Q)MK3 | MFP-238KM-(Q)MK3 | |||
model | FP-34KM-(Q)M1 | FP-51KM-(Q)M1 | FP-68KM-(Q)M1 | FP-80KM-(Q)M1 | FP-85KM-(Q)M2 | FP-102KM-(Q)M2 | FP-136KM-(Q)M2 | FP-136KM-(Q)M3 | FP-153KM-(Q)M3 | FP-170KM-(Q)M3 | FP-204KM-(Q)M3 | FP-238KM-(Q)M3 | |||
model of panel | MB-SD11K1 | MB-SD11K2 | MB-SD11K3 | ||||||||||||
power supply | 220V,50Hz,1Ph | ||||||||||||||
air volume | H | m3/h | 380 | 550 | 680 | 780 | 880 | 1050 | 1300 | 1380 | 1550 | 1750 | 2050 | 2200 | |
M | 300 | 440 | 540 | 620 | 700 | 840 | 1040 | 1100 | 1240 | 1400 | 1640 | 1760 | |||
L | 230 | 330 | 410 | 470 | 530 | 630 | 780 | 830 | 930 | 1050 | 1230 | 1320 | |||
static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||
cooling capacity | TH | H | W | 2000 | 3000 | 3800 | 4200 | 4900 | 5800 | 7000 | 7500 | 8100 | 9800 | 11000 | 12000 |
BTU/h | 6824 | 10236 | 12966 | 14330 | 16719 | 19790 | 23884 | 25590 | 27637 | 33438 | 37532 | 40944 | |||
SH | W | 1400 | 2200 | 2850 | 3300 | 3500 | 4250 | 5250 | 5500 | 5880 | 7150 | 8250 | 9100 | ||
BTU/h | 4777 | 7506 | 9724 | 11260 | 11942 | 14501 | 17913 | 18766 | 20060 | 24396 | 28149 | 31049 | |||
TH | M | W | 1700 | 2550 | 3250 | 3550 | 4150 | 4950 | 5950 | 6400 | 6650 | 8350 | 9350 | 10200 | |
SH | W | 1150 | 1800 | 2350 | 2650 | 2850 | 3500 | 4350 | 4550 | 4700 | 5950 | 6850 | 7650 | ||
TH | L | W | 1400 | 2050 | 2600 | 2900 | 3400 | 4000 | 4850 | 5200 | 5420 | 6750 | 7600 | 8300 | |
SH | W | 950 | 1400 | 1850 | 2100 | 2300 | 2800 | 3450 | 3600 | 3850 | 4700 | 5450 | 6000 | ||
heating capacity | H | W | 3100 | 4700 | 5900 | 6500 | 7600 | 9000 | 10900 | 11600 | 12200 | 15200 | 17100 | 18600 | |
M | W | 2650 | 4000 | 5000 | 5550 | 6450 | 7650 | 9250 | 9850 | 10300 | 12900 | 14550 | 15800 | ||
L | W | 2100 | 3150 | 3950 | 4350 | 5100 | 6050 | 7300 | 7750 | 8140 | 10200 | 11450 | 12450 | ||
noise | H | 0Pa | dB(A) | 39 | 42 | 44 | 46 | 42 | 46 | 48 | 46 | 48 | 47 | 50 | 51 |
power input | H | 0Pa | W | 40 | 50 | 58 | 60 | 70 | 95 | 125 | 130 | 145 | 160 | 190 | 210 |
waterflow volume | m3/h | 0.34 | 0.51 | 0.65 | 0.72 | 0.83 | 0.99 | 1.19 | 1.28 | 1.38 | 1.67 | 1.87 | 2.04 | ||
water pressure dropping | kPa | 11 | 13 | 22 | 25 | 18 | 25 | 30 | 23 | 23 | 28 | 33 | 42 | ||
dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
coil | type | high efficient copper pipe to wear Hydrophilic aluminum coil | |||||||||||||
dimension of water drain pipe | mm | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ||||
net dimension | unit | L×W×H mm | 592*592*242 | 750*750*242 | 840*840*242 | 840*840*292 | |||||||||
panel | 650*650*40 | 850*850*40 | 950*950*40 | 950*950*40 | |||||||||||
net weight | unit | kg | 17 | 18 | 18 | 18.5 | 22 | 23 | 23 | 25 | 26 | 27 | 27 | ||
panel | 2.2 | 4.2 | 5 |
Testing condition:
2-tube system
Cooling
Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC
Entering/out water temperature: 7ºC/ 12?
Heating
Entering air temperature: 20ºC
Entering water temperature: 60ºC, Same water flow rate as for the cooling
PERFORMANCE OF "M" STYLE CASSETTE TYPE FAN COIL(4-WAY,4TUBE)---DRAINED BY WATER PUMP | |||||||||||||||
model(2 tube system) | MFP-34KM4-(Q)MK1 | MFP-51KM4-(Q)MK1 | MFP-68KM4-(Q)MK1 | MFP-80KM4-(Q)MK1 | MFP-85KM4-(Q)MK2 | MFP-102KM4-(Q)MK2 | MFP-136KM4-(Q)MK2 | MFP-136KM4-(Q)MK3 | MFP-153KM4-(Q)MK3 | MFP-170KM4-(Q)MK3 | MFP-204KM4-(Q)MK3 | MFP-238KM4-(Q)MK3 | |||
model | FP-34KM4-(Q)M1 | FP-51KM4-(Q)M1 | FP-68KM4-(Q)M1 | FP-80KM4-(Q)M1 | FP-85KM4-(Q)M2 | FP-102KM4-(Q)M2 | FP-136KM4-(Q)M2 | FP-136KM4-(Q)M3 | FP-153KM4-(Q)M3 | FP-170KM4-(Q)M3 | FP-204KM4-(Q)M3 | FP-238KM4-(Q)M3 | |||
model of panel | MB-SD11K1 | MB-SD11K2 | MB-SD11K3 | ||||||||||||
power supply | 220V,50Hz,1Ph | ||||||||||||||
air volume | H | m3/h | 360 | 520 | 650 | 740 | 840 | 1000 | 1240 | 1320 | 1480 | 1660 | 1950 | 2090 | |
M | 290 | 420 | 510 | 590 | 670 | 800 | 990 | 1050 | 1180 | 1330 | 1560 | 1670 | |||
L | 220 | 310 | 390 | 450 | 500 | 600 | 740 | 790 | 885 | 1000 | 1170 | 1250 | |||
static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
cooling capacity | TH | H | W | 1950 | 2950 | 3700 | 4100 | 4800 | 5700 | 6850 | 7350 | 7940 | 9600 | 10800 | 11750 |
BTU/h | 6700 | 10050 | 12700 | 14050 | 16400 | 19400 | 23400 | 25100 | 27100 | 32750 | 36800 | 40150 | |||
SH | W | 1350 | 2150 | 2800 | 3250 | 3450 | 4150 | 5150 | 5400 | 5773 | 7000 | 8100 | 8900 | ||
BTU/h | 4700 | 7350 | 9550 | 11050 | 11700 | 14200 | 17550 | 18400 | 19650 | 23900 | 27600 | 30450 | |||
TH | M | W | 1650 | 2500 | 3200 | 3500 | 4050 | 4850 | 5850 | 6250 | 6490 | 8200 | 9150 | 10000 | |
SH | W | 1150 | 1750 | 2300 | 2600 | 2800 | 3450 | 4250 | 4450 | 4600 | 5850 | 6700 | 7500 | ||
TH | L | W | 1350 | 2000 | 2550 | 2850 | 3350 | 3900 | 4750 | 5100 | 5315 | 6600 | 7450 | 8150 | |
SH | W | 950 | 1350 | 1800 | 2050 | 2250 | 2750 | 3400 | 3550 | 3800 | 4600 | 5350 | 5900 | ||
heating capacity | H | W | 1950 | 3000 | 3750 | 4150 | 4850 | 5750 | 6950 | 7400 | 7780 | 9700 | 10900 | 11850 | |
M | W | 1700 | 2550 | 3200 | 3550 | 4100 | 4850 | 5900 | 6250 | 6535 | 8200 | 9250 | 10050 | ||
L | W | 1350 | 2000 | 2500 | 2750 | 3250 | 3850 | 4650 | 4950 | 5200 | 6500 | 7300 | 7950 | ||
noise | H | 0Pa | dB(A) | 39 | 42 | 44 | 46 | 42 | 46 | 48 | 46 | 48 | 47 | 50 | 51 |
power input | H | 0Pa | W | 40 | 50 | 58 | 60 | 70 | 95 | 125 | 130 | 145 | 160 | 190 | 210 |
waterflow volume | Cooling | m3/h | 0.33 | 0.5 | 0.64 | 0.71 | 0.81 | 0.97 | 1.17 | 1.25 | 1.4 | 1.64 | 1.83 | 2 | |
Heating | 0.22 | 0.33 | 0.42 | 0.46 | 0.54 | 0.64 | 0.77 | 0.82 | 0.86 | 1.08 | 1.21 | 1.32 | |||
water pressure dropping | Cooling | kPa | 11 | 13 | 22 | 25 | 18 | 25 | 30 | 23 | 23 | 28 | 33 | 42 | |
Heating | 7 | 8 | 13 | 14 | 11 | 15 | 21 | 15 | 15 | 19 | 23 | 26 | |||
dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
coil | type | high efficient copper pipe to wear Hydrophilic aluminum coil | |||||||||||||
dimension of water drain pipe | mm | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ?26 | ||||
net dimension | unit | L×W×H mm | 592*592*242 | 750*750*242 | 840*840*242 | 840*840*292 | |||||||||
panel | 650*650*40 | 850*850*40 | 950*950*40 | 950*950*40 | |||||||||||
net weight | unit | kg | 19 | 20 | 20 | 20.5 | 24.5 | 25.5 | 25.5 | 27.5 | 29.5 | 29.5 | 30 | ||
panel | 2.2 | 4.2 | 5 |
Testing condition:
4-tube system
Cooling
Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC
Entering/out water temperature: 7ºC/ 12ºC
Heating
Entering air temperature: 20ºC
Entering/out water temperature: 60ºC/ 50ºC
Products Feature and details
1 Distinctive panel design
*4-way air flowing, which can uniform temperature distribution in the room. Elegant appearance can let our fan coil unit match different decoration style.
2 The dimension of M1 unit is only 590*590mm, which can be installed in a standard ceiling opening. In addition the thickness is 240mm
3 Specially panel design to avoid air-short flowing.
4 Remote controller is standard and wire controller is optional
5 Excellent performance-Integral C type heat exchanger
*All adopt the design of integral C type structure, well-distributed air volume and high-efficient heat exchange ;
*All adopt of cooling coils with 9.52mm copper pipe, reasonable distribution of flow path and reduction of water resistance;
*All adopt the hydrophilic coating aluminum fins;
*With large diameter vortex fan, high air volume and low noise;
*Stick the porous plastic foaming sponge to the internal of units for the heat insulation and noise absorption ;
*Stick the heat insulation sponge around the whole
surface of units to prevent the condensation;
6 BLDC motor is optional
Our K style DC motor cassette type fan coil unit use Panasonic BLDC motor which take higher efficiency and more energy saving than AC motor. Using DC motor can get distinct energy conservation than normal AC motor.
7 Excellent performances-the dependable solution of draining the condensed water
*Adopt the drainage pump with large flow and high-lift,the actual lift can reach to 1.2m, meet the needs of drainage arrangement in all kinds of places;
*The design of water level switch auxiliary drainage;
----Excellent performance of pump, which can work a long time in the condition of no water;
----The warning and preventing leakage function of water level switch;
*Reasonable distribute the running time of pump according to the units' working condition;
*The gradient drainage design of drain tray makes the water stay in the least state;
*The design of auxiliary drain tray avoids the leakage incidents caused by the improper heat presentation in the external of units
8 High lift water drained pump (750mm)
9 Float switch inside to prevent from leaking
10 The structure of the unit is easy for maintaining fan and fan motor.
11 Easily interfaced with most widely used Mod-bus and proprietary supervisory system based on Mod-bus protocol.
12 Left/right water tube connection can be selected
13 Air-cleaning function can be selected, we offer negative ion generator as optional parts.
14 4-tube system is optional
15 Water valve can be installed inside the unit.
Product certification:
Packing and shipping
FAQ.
Q:Can you manufactury do OEM for our company?
A: Yes of course. As a specialized manufacturer and exporter for this product in China, we sincerely hope to establish business relations with your esteemed corporation. Now we do OEM/ODM for a lot of famous brands in China and other countries, such as, KingAir, QingHuaTongFang,TCL,AUX,CHIGO,LS,etc.
Q: How long is your warranty?
A: We offer 18 months warranty for our products. We offer free repair parts and professional technical support.
Q: Our hotel want to choose the fan coil unit which have 4 pipe system, do you have this one?
A: Yes, Most of our products have 4 pipe system as optional.
- Water Cassette Fan Coil Unit (K) with Pump 5 Pieces / (Min. Order)
- 4 Way Cassette Fan Coil Unit (K) with Pump 5 Pieces / (Min. Order)
- 4 Way Cassette Fan Coil Unit (E) without Pump 5 Pieces / (Min. Order)
- Water Cassette Fan Coil Unit (E) with Pump 5 Pieces / (Min. Order)
- 4-way Cassette Fan Coil Unit (M) with Pump 5 Pieces / (Min. Order)
- One Way Blowing Cassette Unit 5 Pieces / (Min. Order)
- One Way Cassette Fan Coil Unit 5 Pieces / (Min. Order)